Shopping security
Built for tradies: The Embraco Aspera NEU6212GK is a compact, hermetic R134a HBP compressor sized for display fridges, reach-ins and small merchandisers. It helps licensed techs get reliable pull-down, fewer call-backs and cleaner installs — no dramas.
With CSIR high start torque, it kicks over on warm heads and tight systems so you’re off the ladder faster and onto the next job. Too easy.
Trade yarn: steamy arvo in Brisbane and the drinks merchandiser kept drifting up around lunch. We swapped in a NEU6212GK, fitted a fresh drier, nitrogen-pressure-tested, pulled to <500 microns and weighed the charge — case temps were back on setpoint before smoko. Fair dinkum difference when the duty and application match.
Need broader spares? Browse our Refrigeration collection for tools and parts that keep systems humming.
Replace the liquid-line drier and purge with nitrogen while brazing. Verify with a decay test after hitting target microns. Log SH/SC and weigh the charge — you’ll cut call-backs and keep customers happy. No worries.
| Item | Spec |
|---|---|
| Model / Eng. code (typ.) | NEU6212GK / 958HA51… (e.g., 958HA51M1AJ) |
| Power supply | 220–240 V, 50 Hz, 1-ph |
| Application | HBP (R134a); verify code if R404A MBP/HBP |
| Displacement | ~8.77–8.78 cm³ |
| Height / Weight | ~200 mm / ~10.6 kg |
| Oil / charge | POE (ester) ISO 22 / ~350 ml |
| Start components | CSIR; start capacitor 53–64 µF / 330 V (typ.) |
| LRA (typ.) | ~19 A |
| Tube stubs (typ.) | Suction Ø 8.1 mm; Discharge Ø 6.1 mm; Process Ø 6.1 mm |
| Base | UNI (European) |
| Performance reference | Example: ~0.83 kW @ −10 °C evap (R404A condensing unit with NEU6212GK); ~1.21 kW @ 0 °C. Use as orientation only — confirm for R134a duty. |
Specs and figures drawn from Embraco technical data and distributor documentation; confirm against the compressor nameplate for the exact code supplied.
Backed by manufacturer warranty. See our Shipping & Returns policy. Standard Australian consumer guarantees apply.
Often, yes if the duty matches. Check base footprint (UNI), tube sizes (8.1/6.1 mm), and capacity at your design temps. Replace the drier, evacuate properly and weigh the charge.
Typical CSIR start cap is 53–64 µF / 330 V. Confirm the supplied kit and the nameplate for your unit.
This listing covers R134a HBP duties. Some engineering codes for NEU6212GK target R404A MBP/HBP — always verify the nameplate and follow AU licensing and the AIRAH code of practice for safety and compliance.
For AU/NZ compliance and handling guidance, see AIRAH’s Refrigerant Handling Codes of Practice.